PRODUCT USER MANUAL

HOME CARE OXYGEN CONCENTRATOR

MODEL NO: DE- 2AĀ DEDAKJ

Ā 

Ā 

Ā 

BRAND INTRODUCTION

Ā 

DE- 2A Oxygen concentrator is designedĀ byĀ DEDAKJ Medical lnstrument Co. , Ltd . DEDAKJ Health company is a long-standing professional manufacturer that isĀ engagedĀ inĀ healthĀ careĀ productsĀ designĀ andĀ manufacturing establishment ,Ā theĀ companyĀ holdsĀ theĀ operationĀ conceptsĀ ofĀ being trustĀ worthyĀ andĀ honesty- based ,devotedĀ toĀ theĀ researchĀ and development,manufacturer,Ā marketingĀ andĀ serviceĀ ofĀ healthĀ care products.Ā BasedĀ onĀ customer ' SĀ demands ,Ā weĀ haveĀ launchedĀ medical oxygenĀ generatorsĀ andĀ oxygenĀ preparationĀ equipmentĀ withĀ multiple functions.TheĀ companyĀ continuouslyĀ integratesĀ theĀ resources about the key component of oxygen generating, and actively explores the business s tratgy on technological innovation and brandĀ  marketing,Ā SoĀ asĀ toĀ developĀ intoĀ theĀ leadingĀ professionalĀ oxygen generatingĀ enterprise,Ā providingĀ qualified andĀ costĀ effectiveĀ oxygen concentrator for existing and new customers. DEDAKJĀ Health company has highly experienced technical personnel, with high-quality team that can provideĀ integratedĀ andĀ timelyĀ serviceĀ toĀ customers ." professional qualifications ,Ā brandĀ creation "Ā isĀ theĀ businessĀ objective." Excellent quality, reliable service " is the operating principle. with huge advantages ofĀ talentedĀ personnel,resources,network,enterprise,Ā scaleĀ and experience, the company hasĀ becomeĀ aĀ newĀ brandĀ enterpriseĀ which hasĀ highlyĀ competitiveĀ andĀ leadingĀ edgeĀ advantages. DEDAKJĀ Health company prides itself on quality, develops with good service, to produce highĀ qualityĀ andĀ affordableĀ priceĀ oxygenĀ generatingĀ products.

Ā 

Operating Principle

The air comes into the compressor after compressed by air inlet filter unitĀ and then it enters into molecular sieve tower to separate the oxygen andĀ nitrogen. The oxygen successfully goes through the molecular sieve towerĀ into the fine sieve tower, In contrast, the nitrogen is absorbed by theĀ molecular, then to be discharged into the atmosphere through theĀ separating valve. The oxygen concentration is enhanced in the fine sieveĀ tower and controlled flow size by flowmeter, Then the oxygen is humidifiedĀ by the humidifying water tank when it comes to it. Finally, the oxygenĀ reached the user through oxygen supply tube.

Ā 

CONTENTS

Safety precautions

Product features

Key technical indexes

Installation and usage

Care and maintenance

Common trouble-shooting

Operation principle

Ā 

Safety precautions

In case of power outage and malfunction of theĀ oxygen concentrator, an alternate source ofĀ supplemental oxygen (such as oxygen cylinder or oxygen bag)should be prepared for the user in urgent need of oxygen.The machine is not intended as medical device and is not toĀ be used for life support or life extension.

Ā 

Pre-installation

Upside down operation is prohibited.

If the power supply has unstable voltage, or isĀ beyond AC220+22(110+10)volt, please connect theĀ voltage regulator before using the machine.

Please use standard socket with safetyĀ qualification and terminal board with electricalĀ safety certification.

Ā 

Laying Place

The machine should be located in a well-ventilatedĀ space and avoid direct sunlight. The distanceĀ between the machine and the wall or other objectsĀ should be no less than 10cm.

Do not put other things or liquid vessel on theĀ machine.

There should not be any obstruction around the airĀ outlet on the back and bottom of the machine,inĀ case of air inlet and air outlet blocked,which could lead to high temperature that will result in machinesĀ stoppage and decreasing of oxygen concentration.

Ā 

Using

Oxygen is a combustion-supporting gas,so do notĀ smoke and keep away from combustion sourceĀ while using the machine for fear ofĀ fire accident.Do not switch on & off frequently. You can restart itĀ after you have switched it off for 3-5 minutesĀ considering its service life.Avoid oil or grease-like material for any part of theĀ machine.So as not to pollute the oxygen machineĀ and cause fire.

Ā 

Product feature

The scope of product application: The product isĀ designed in accordance with standard of HomeĀ personal usage appliance,Health function: improved oxygen absorption can improveĀ the condition of the body to achieve the purpose ofĀ oxygen health care.Applicable to the elders, poorĀ physique,pregnant women,students,and athletesĀ restore physical function.

Ā 

Function Feature

Intelligent control: LED display screen, easy use and

operations operate for timing function.Overheat protection: the pure oil-free air compressor with overheat protector, will stop working automatically when the compressor's working temperature is too high to protect the compressor and the whole part of the product.

Ā 

Operating principle

This product uses AC220V/110V as power source, air as raw material and adopts the pure oil-free air compressor and qualified molecular sieve imported with original packaging,so as to generate high purity oxygen by PSA at normal temperate and supply oxygen.

Ā 

Key Technical Indexes

Product name: Oxygen concentrator

Model: DE-2A

Oxygen generation method: Pressure Swing Adsorption PSA)

Rated voltage:AC220+22V 50+1HZ/AC110+10V 60Hz

Rated power: 200VA

Oxygen flow rate:2L-9L/min adjustable

Oxygen concentration:30%-90%adjustable

Oxygen pressure:0.02-0.08MPa

Carbon dioxide: qualified according to the specified method

pH value: qualified according to the method

Morphological identification: odorless,specified colorless gasļ¼Œcombustion-support

Operating noise:ā‰¤45dB(A)

Classification: class II

Size:404mmx182mmx383mm

Net weight: 8.0kg

Display control: LED light display, Intelligent chip control, infrared remote control

Ā 

dedakj oxygen concentrators

Installation and Usage

Open-package inspection

After opening the package, please check whether the machine is in good condition, and refer to the accessory list to ensure that it has included all of the items. lf there is any missing item, please contact your supplier or manufacturer in time for replacement.

Ā 

Ā 

Preparation Work

Filling water in humidification water tank:Grip the top handle of the humidification water tank by hand, pull out the water tank after pressing.

Ā 

Open silica gel plug at top and fill pure water to the highest water level line.(Cool boiled water, distilled water and so on)*Do not exceed water level line.

Ā 

Make sure to cover the rubber plug before using, alignĀ the positioning groove at the bottom of water tank andĀ then the outlet,put the humidification water tank backĀ to the main body.

Ā 

Connect oxygen tube:Connect one end of "Oxygen tube" with "oxygenĀ outletĀ mouth", and connect the other end with oxygenĀ inhaler.

Ā 

Ā 

Inhale Oxygen Operation

LED screen display instruction

  1. Sleep function: The machine engage in sleep modeautomatically after running for 3 minutes,the screenĀ lights dimmed to power saving.
  2. Cooling fan indicator
  3. Timing setting indicator
  4. (Generating oxygen indicator
  5. Cumulative time indicator.

Ā 

Ā 

  1. Electricity

When the oxygen machine is power on, open theĀ power switch on the shell, the buzzer sounds for aĀ long time , then LED screen light.

Ā 

  1. Power on

Press the key" generate oxygen",the machineĀ will start,open the cooling fan,timing settingĀ function,generate oxygen function,CumulativeĀ time function and brand logo light synchronously,there is LED display light and blue light in water tank.

Ā 

  1. Timing +

Lightly touch the "Timing+" key, the timing is set toĀ be 15 minutes.The timing setting is one-wayĀ circulation setting. The highest value is 180minutes;Ā 3 seconds after you have done the timingĀ operation,the timer will start into a countdown process.The operation of the "Timing-" key is the same withĀ the "Timing +" key.

Ā 

  1. Flow rate setting key

Through regulating valve knob to control the oxygen flowĀ and concentration,the greater the flow,the smaller theĀ oxygen concentration.

Ā 

  1. Infrared remote control

The remote control key function is the same with controlĀ panel key function.

Ā 

Remote Control Instructions

(1)0n/0ff key

(2)Timing + key

(3)Timing-key

(4)Sleep mode key

Ā 

In working state, press "Sleep" mode key, the "Sleep" iconĀ on the display screen will flash three times, then theĀ screen will turn into sleep mode. Press any key on theĀ remote control or touch any key on the machine panel toĀ active the screen highlight.

Ā 

Normal Operating Conditions

Operational temperature:5Ā°C-40Ā°CĀ 

Relative humidity range:ā‰¤80%RHĀ 

Atmospheric pressure range: 86 kPa-106 kPa

Ā 

When the temperature is below 5Ā°C,the machine should beĀ put in normal operating condition for at least 4 hoursĀ before getting started.

Ā 

Transport or storage conditionsĀ 

Storage temperature:-20Ā°C-60Ā°C

Relative humidity range:ā‰¤93%RH

Ā 

To avoid strong electromagnetic interference environmentĀ or interfering other domestic appliances, please keep theĀ machine at least 3m away from other domestic appliances.

Ā 

Symbols for safety requirement and meaning on the machineĀ Class ll equipment

Ā Click to buy: The original DEDAKJ oxygen accessories oxygen parts

(DEDAKJ Original Oxygen filter, Water Tank,Ā Ā Remote Control,Ā Oxygen cannula, Silicon oxygen tube,Ā  32.8 feet Pro-long clear silicon oxygen tube, and Oxygen mask)

Care and Maintenance

  1. Cleaning housing unit

The surface of the housing should be cleaning at leastĀ once every month.Disconnect the power cord beforeĀ you clean it. Wipe it with a clean, mild, damp cloth soakedĀ with disinf-tant, Do not let the liquid penetrate into the machine.

Ā 

  1. Cleaning water tank

To keep the water tank clean,the water used shouldĀ be purified water, distilled water or cold boiled water.we suggest to change water every day.

Ā 

The water tank should be cleaned every week. First useĀ mild detergent and shake the tank to wash. Then useĀ clean water to rinse it,

Ā 

After cleaned the water tank,please remember to putĀ water tank plastic plug back to avoid leakage of oxygenĀ from the water inlet, caused no oxygen output fromĀ oxygen outlet mouth when the machine is in normalĀ working.

Ā 

Ā 

  1. Air filter cleaning

The white air filter at the back of the machine canĀ reduce noise,isolate dust and purify the air. lt should beĀ clean. lt should be cleaned around every ten days. FirstĀ use mild detergent to wash, and then rinse it with cleanĀ water. Pay special attention that it must be dry to beĀ positioned back,or the function of the molecular sieveĀ could be damaged,which will lead to decreased oxygenĀ concentration.

* The air filter should be replaced every 2-4 months, depending on the usage environment.

Ā 

  1. Oxygen tube and oxygen inhaler cleaning

In general condition,it should be cleaned every threeĀ days. The snorting part of nasal cannula should beĀ cleaned after each use. You can soak it with 5%Ā potassium permanganate solution for 5 minutes,thenĀ rinse with clean water, or wipe it with alcohol. Change anew oxygen tube every year.

Ā 

  1. Long-term storage operations

Before you long-term storage the oxygen concentrator, pleaseĀ do as follows:

Ā 

  1. Bring down the humidifier water tank, pull out the water,dry it and position it back.

2.Disconnect the power cord and put away the power cord.3. Do not place please the machine in damp, dusting environment.Avoid direct sunlight and pollution. Preserve the oxygenĀ tube and oxygen inhaler at room temperature. Do not twistĀ the airway tube. Keep out of the reach of the children.

Ā 

Ā 

Do as follows before restart the machine after long-termĀ storageĀ period:

  1. Make sure the power cord is undamaged.
  2. Clean the oxygen tube and oxygen inhaler. Check whetherthe tube is blocked or twisted. Please straighten out.
  3. Clean the humidifier water tank.

Ā 

Common Trouble-shooting

Ā 

If it still does not work as you have followed the solutions listed aboveĀ do not disassemble the machine, Please consult the manufacturer forĀ assistance.

Ā 

Contact DEDAKJ Office